為了實(shí)現(xiàn)數(shù)據(jù)機(jī)房的長(zhǎng)期穩(wěn)定運(yùn)行,改善IT設(shè)備的運(yùn)行環(huán)境,服務(wù)器機(jī)柜的溫度應(yīng)控制在相應(yīng)范圍內(nèi),局部熱點(diǎn),降低服務(wù)器機(jī)柜的局部溫度。下面讓我們來(lái)介紹一下如何解決服務(wù)器機(jī)柜的局部高熱問題,希望對(duì)大家有所幫助。
In order to achieve long-term stable operation of the data room and improve the operating environment of IT equipment, the temperature of the server cabinet should be controlled within the corresponding range, eliminate local hotspots, and reduce the local temperature of the server cabinet. Let's introduce how to solve the local high heat problem of server cabinets, hoping to be helpful to everyone.
一、在沒有空調(diào)的機(jī)房?jī)?nèi),機(jī)柜可以通過配置網(wǎng)門和頂部加裝風(fēng)扇的方式增加散熱效果,降低設(shè)備的運(yùn)行溫度。
1、 In a computer room without air conditioning, the cabinet can increase heat dissipation and reduce the operating temperature of the equipment by configuring a mesh door and installing a fan at the top.
二、在機(jī)房里有空調(diào)的情況下,可以通過以下措施降低IT設(shè)備的運(yùn)行溫度。
2、 When there is air conditioning in the computer room, the following measures can be taken to reduce the operating temperature of IT equipment.
配置冷通道機(jī)柜系統(tǒng)或熱通道機(jī)柜系統(tǒng)。其原理為:通過對(duì)機(jī)房氣流進(jìn)行控制來(lái)節(jié)省制冷能耗和提高服務(wù)器運(yùn)行穩(wěn)定性已是數(shù)據(jù)機(jī)房建設(shè)者的常用措施;冷熱通道分離方法、機(jī)柜內(nèi)使用擋風(fēng)板和假面板防止熱空氣無(wú)序流竄等等也已是成熟的簡(jiǎn)單技術(shù)。一般機(jī)房的機(jī)柜布置,遠(yuǎn)離主機(jī)房空調(diào)的機(jī)柜內(nèi)設(shè)備無(wú)法得到有效的散熱,機(jī)柜內(nèi)設(shè)備處于高溫環(huán)境下運(yùn)行,要想使遠(yuǎn)離主機(jī)房空調(diào)的機(jī)柜內(nèi)設(shè)備得到有效散熱,要么增加輔助空調(diào),要么再降低主機(jī)房空調(diào)的冷氣溫度,都將增加能耗。冷通道機(jī)柜系統(tǒng)或熱通道機(jī)柜系統(tǒng)主要用于設(shè)備密度較大的機(jī)柜的機(jī)房,通過冷風(fēng)的定向流動(dòng)達(dá)到局部熱點(diǎn)以及的目的。當(dāng)局部機(jī)柜發(fā)熱量大于其他同一通道內(nèi)的機(jī)柜時(shí),可采用在對(duì)應(yīng)機(jī)柜旁增加列間空調(diào)或在開孔靜電地板上增加向上吹氣的風(fēng)扇和控制氣流方向的百葉窗,以增加此機(jī)柜進(jìn)氣側(cè)的進(jìn)氣量來(lái)解決散熱的問題。
Configure a cold channel cabinet system or a hot channel cabinet system. The principle is that controlling the airflow in the data room to save cooling energy consumption and improve server operation stability has become a common measure for data room builders; The separation method of cold and hot channels, the use of wind deflectors and fake panels inside the cabinet to prevent the disorderly flow of hot air, and so on, are also mature and simple technologies. In general, the layout of equipment cabinets in a computer room cannot effectively dissipate heat for equipment located far away from the air conditioning system in the main room. The equipment inside the cabinets operates in a high-temperature environment. To effectively dissipate heat for equipment located far away from the air conditioning system in the main room, either auxiliary air conditioning should be added or the air conditioning temperature in the main room should be lowered, which will increase energy consumption. The cold channel cabinet system or hot channel cabinet system is mainly used in equipment rooms with high equipment density, to eliminate local hot spots and achieve energy conservation and environmental protection through the directional flow of cold air. When the heat generation of a local cabinet is greater than that of other cabinets in the same channel, the problem of heat dissipation can be solved by adding inter column air conditioners next to the corresponding cabinet or adding upward blowing fans and louvers controlling the airflow direction on the perforated electrostatic floor to increase the air intake on the intake side of this cabinet.
This article is organized and published by Jinan Chassis Cabinet. Have you gained some understanding of these contents? For more information, please click on: http://www.26huojia.com We will have more exciting content waiting for you to check out.